2024 Latest NS0-516 DUMPS Q&As with Explanations Verified & Correct Answers [Q21-Q44]

Share

2024 Latest NS0-516 DUMPS Q&As with Explanations Verified & Correct Answers

NS0-516 dumps Exam Material with 66 Questions


The Network Appliance NS0-516 exam comprises challenging questions that require candidates to demonstrate their proficiency in SAN design, deployment, as well as the management of NetApp E-Series storage systems. NetApp Implementation Engineer SAN Specialist E-Series (NCIE) certification program is designed to equip candidates with the skills needed to create a comprehensive data storage system that meets the demands of today's high-performance IT environments.


The NS0-516 exam consists of 60 multiple-choice questions, which must be completed within 1.5 hours. NS0-516 exam covers a wide range of topics, including NetApp E-Series storage architecture, installation and configuration, data protection and disaster recovery, performance optimization, and troubleshooting.

 

NEW QUESTION # 21
All non-I/O related activity on the storage system is recorded in the _____________. (Choose the best answer.)

  • A. DACstore
  • B. NVSRAM
  • C. Storage Array Profile
  • D. Cache backup device
  • E. Event Log

Answer: A


NEW QUESTION # 22
A customer is running several EF570 systems and uses the ability of the EF-Series systems to run two host protocols at the same time. You are installing a new EF570 that uses the NVMe protocol for a high performance computing application. The controller on-board ports will not connect, but the HIC ports are working fine.
In this scenario, what is the problem?

  • A. The on-board ports have the wrong SFPs for the desired network protocol
  • B. There is a cable fault preventing the on-board ports from connecting
  • C. The switch ports are shut-down
  • D. The on-board host ports are disabled

Answer: A

Explanation:
* EF570 Systems: The EF570 supports multiple host protocols simultaneously, including NVMe.
* Connection Issue: The controller on-board ports not connecting while HIC ports are working fine suggests a potential configuration issue.
* SFP Mismatch: The most likely cause is that the on-board ports have the wrong Small Form-factor Pluggable (SFP) modules installed for NVMe protocol.
* Solution: Ensure that the correct SFPs for NVMe protocol are installed in the on-board ports.
References: NetApp E-Series Hardware Installation Guide, Host Protocol Configuration section.


NEW QUESTION # 23
Exhibit:

Referring to the exhibit, which three steps would you take to solve the problem shown in the event log? (Choose three.)

  • A. Swap out the HBA on the FC switch
  • B. Reinitialize the FC switch
  • C. Swap out the SFP in the controller port
  • D. Swap out the FC cable
  • E. Move the connection to another controller port

Answer: B,C,D


NEW QUESTION # 24
A customer has launched a data analytics initiative and has been transferring old data into the new data lake.
The customer has discovered some data read errors during the transfer process.
In this scenario, how should the customer have avoided these data integrity issues?

  • A. by ensuring that data assurance and media scan are always activated
  • B. by turning on erasure coding
  • C. by turning on cyclic redundancy checks (CRCs)
  • D. by deploying secure-capable drives

Answer: A


NEW QUESTION # 25
When working on a customer's E-Series system to configure LDAP, you realize that you need to complete a Certificate Signing Request to receive a certificate.
In this scenario, when entering the information for the CSR, what information do you need from the controllers themselves? (Choose three.)

  • A. the controller's alternate IP addresses
  • B. the controller's geographical location
  • C. the controller's alternate names
  • D. the controller's serial number
  • E. the controller's common name

Answer: B,C,E

Explanation:
* When completing a Certificate Signing Request (CSR) for an E-Series system, you will need:
* The controller's geographical location: This is typically the city or locality and the country where the controller is located.
* The controller's common name: This is usually the fully qualified domain name (FQDN) of the controller.
* The controller's alternate names: These may include additional domain names or IP addresses that the certificate should also cover.


NEW QUESTION # 26
What is the total number of ALUA paths from the host to a volume on the EF280 that is shown in the exhibit?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 27
What file on a Windows management host server contains information about the storage system management connections?

  • A. mgmt.cfg
  • B. EMWdata_vxx.bin
  • C. AMWcfg_vxx.bin
  • D. the event log

Answer: B


NEW QUESTION # 28
An administrator is asked to provision a 1 TB volume to hold non-critical temporary data for a seismic-analysis application. The volume requires the highest possible IOPS.
In this scenario, which configuration would satisfy this requirement?

  • A. RAID 6 Dynamic Disk Pool with a 32 KiB segment size
  • B. RAID 6 Dynamic Disk Pool with a 256 KiB segment size
  • C. RAID 5 volume group with a 256 KiB segment size
  • D. RAID 0 volume group with a 32 KiB segment size

Answer: C


NEW QUESTION # 29
Your AutoSupport does not automatically send reports to NetApp's ActiveIQ tool.
In this scenario, how do you access the data that would have been sent using the AutoSupport feature?

  • A. Access the event log by using SANtricity System Manager
  • B. Use SANtricity Unified Manager to collect the support data remotely
  • C. Use SANtricity System Manager to manually collect the support data
  • D. Ask NetApp Support to help you to access the data by using special support tools

Answer: C


NEW QUESTION # 30
In which two locations would you find the WWPNs for a Windows host? (Choose two)

  • A. Windows Device Manager
  • B. HBA vendor's utility
  • C. FC switch
  • D. host's BIOS

Answer: B,C


NEW QUESTION # 31
A customer has launched a data analytics initiative and has been transferring old data into the new data lake. The customer has discovered some data read errors during the transfer process.
In this scenario, how should the customer have avoided these data integrity issues?

  • A. by ensuring that data assurance and media scan are always activated
  • B. by turning on erasure coding
  • C. by turning on cyclic redundancy checks (CRCs)
  • D. by deploying secure-capable drives

Answer: A


NEW QUESTION # 32
How many partitions are being used in this storage system?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 33
You are troubleshooting a customer issue on their E-Series system. You need information on the volume configuration of the customer's system.
In this scenario, which log would you download to get the required information?

  • A. Health Image
  • B. Trace Buffers
  • C. IO Path Statistics
  • D. Support Data

Answer: D


NEW QUESTION # 34
Exhibit:

Referring to the exhibit, which SAS connector is supported on the NetApp E2800 E-Series family?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B


NEW QUESTION # 35
Your company has an E-Series system connected to Cisco MDS switches. You are asked to provision a volume on a new Windows host, but the Windows host is unable to connect to the volume on the E-Series system. All other Windows hosts in the fabric are able to connect to their volumes.
In this scenario, which three actions should you perform to accomplish this task? (Choose three.)

  • A. Restart the switches
  • B. Add a zone to the active zoneset
  • C. Create a single-initiator zone with the host and E-Series system
  • D. Obtain the WWPN for the Windows HBA
  • E. Create a new virtual SAN (VSAN)

Answer: B,C,D

Explanation:
To resolve the issue of a new Windows host being unable to connect to a volume on the E-Series system when all other hosts can, follow these steps:
* Obtain the WWPN for the Windows HBA (B):The Worldwide Port Name (WWPN) is essential for zoning and establishing communication between the host and the storage system. Ensure you have the correct WWPN for the new Windows host's HBA.
* Create a single-initiator zone with the host and E-Series system (D):Zoning is crucial in SAN environments to control and secure the data paths. Create a single-initiator zone that includes the WWPN of the Windows host and the target ports of the E-Series system. This ensures that the host can see the storage.
* Add a zone to the active zoneset (E):After creating the necessary zone, it needs to be added to the active zoneset on the Cisco MDS switch. The zoneset must then be activated for the changes to take effect, enabling the new host to communicate with the E-Series system.
These steps ensure that the new Windows host is properly zoned and can access the storage volumes without disrupting the existing configurations.
References:
* NetApp E-Series SANtricity Storage Manager Documentation
* Cisco MDS Switch Configuration Guide


NEW QUESTION # 36
Which three factors should you consider before you install an E2860 in a data center? (Choose three.)

  • A. heat dissipation
  • B. electromagnetic interference
  • C. ambient temperatures
  • D. current draw
  • E. fire suppression capacity

Answer: A,C,D

Explanation:
* Current Draw: It is important to consider the electrical current draw of the E2860 to ensure that the data center power infrastructure can support it without overloading circuits.
* Heat Dissipation: The heat generated by the E2860 needs to be accounted for in the data center's cooling design. Proper heat dissipation mechanisms must be in place to prevent overheating.
* Ambient Temperatures: The operating environment's temperature should be within the specified range for the E2860 to function correctly and reliably. Ensuring that the ambient temperatures are controlled is crucial for optimal performance and longevity of the equipment.
References:
* NetApp E-Series Installation and Configuration Guide
* NetApp Implementation Engineer - SAN Specialist - E-Series manuals


NEW QUESTION # 37
To enable one-way authentication in a new iSCSI Linux implementation, which three modifications should you make in the /etc/iscsi/iscsi.conf file on the Linux host? (Choose three.)

  • A. CHAP
  • B. iSCSI
  • C. sendtargets discovery
  • D. the target username and password
  • E. the initiator username and password

Answer: A,C


NEW QUESTION # 38
For SAN zoning of E-Series systems, what type of relationship between host ports and storage system ports is a common industry practice?

  • A. two-to-two
  • B. many-to-one
  • C. one-to-one
  • D. many-to-many

Answer: C


NEW QUESTION # 39
What is the SANtricity Client? (Choose the best answer.)

  • A. An OS-dependent collection of utilities for servers attached to SANtricity-managed storage systems
  • B. A host I/O performance modeling interface
  • C. A GUI or CLI run on a host server used for storage system management
  • D. A host server process that enables storage system management with the storage data path
  • E. Inter-process communication that supports computer program subordinates

Answer: A


NEW QUESTION # 40
What are two base host connectivity selections that are provided by the E2800 controller? (Choose two.)

  • A. FC
  • B. SAS
  • C. iSCSI
  • D. IB

Answer: A,C


NEW QUESTION # 41
Schedules for AutoSupport's periodic collection of data can be changed in the ________. (Choose the best answer.)

  • A. Major Event Log
  • B. NVSRAM
  • C. Enterprise Management Window
  • D. Array Management Window

Answer: C


NEW QUESTION # 42
Which statement describes a drive channel?

  • A. It is replicated for each controller.
  • B. It is the physical Ethernet link between the host and disk shelves that transfers controller commands.
  • C. It is the physical SAS link between a controller shelf and disk shelves that transfers I/O data.
  • D. It is defined by a host connection.

Answer: C


NEW QUESTION # 43
Hot spares provide which function? (Choose the best answer.)

  • A. None of the above
  • B. reserve capacity for disk pools
  • C. reserve capacity for volume groups
  • D. efficiency for volumes
  • E. both "efficiency for volumes" and "reserve capacity for disk pools"

Answer: E


NEW QUESTION # 44
......


Network Appliance NS0-516 exam is a certification exam that is designed for IT professionals who specialize in implementing NetApp SAN solutions. NS0-516 exam is known as the NetApp Implementation Engineer SAN Specialist E-Series (NCIE) exam and it is an advanced-level certification that validates the skills and knowledge of IT professionals in implementing SAN solutions using NetApp E-Series storage systems.

 

Share Latest NS0-516 DUMP Questions and Answers: https://www.pass4leader.com/NetworkAppliance/NS0-516-exam.html

NS0-516 Questions and Answers Guarantee you Oass the Test Easily: https://drive.google.com/open?id=1z3EGq90HSeLw6B98by7Ogyq6Eotu53of